![]() ![]() This next step below, will enable the static fan control for the server with IPMI. If you want to verify the directory type in ” dir “.īelow is an example: ipmitool.exe -l lanplus 0.0.0.0 -U root -P Password raw 0x30 0x30 0x01 0x00 – Replace all required fields with your own information. Open Command Prompt and Change Directory to C:\Program Files (x86)\Dell\SysMgt\bmc Login into iDRAC web interface, Go to iDRAC Settings – > Network -> IMPI over LAN (Enable it) Ipmitool -I lanplus -H -U -P sdr list full Ipmitool -I lanplus -U -P raw 0x30 0x30 0x02 0xff 0x2D This will verify Servers SDR Ipmitool -I lanplus -H -U -P raw 0x30 0x 30 0x01 0x00 This sets the Fans to a Static Speed to 45% Replace with iDRAC admin password This Enables Static Fan Control Enable static fan control: ipmitool -I lanplus -H -U -P raw 0x30 0x30 0x02 0xff 0x2DĮnable IMPI over LAN within iDRAC7 Web Interface. ![]() Disable manual/static fan control: ipmitool -I lanplus -H -U -P raw 0x30 0x30 0x01 0x01.Enable manual/static fan control: ipmitool -I lanplus -H -U -P raw 0x30 0x30 0x01 0x00.Senors read out: ipmitool -I lanplus -H -U -P sdr list full. ![]()